{"id":106,"date":"2020-11-14T20:24:33","date_gmt":"2020-11-14T20:24:33","guid":{"rendered":"http:\/\/titesting.ca\/?post_type=product&#038;p=106"},"modified":"2023-05-31T15:14:14","modified_gmt":"2023-05-31T20:14:14","slug":"load-cell-universal-hardness-tester","status":"publish","type":"product","link":"https:\/\/titesting.ca\/index.php\/product\/load-cell-universal-hardness-tester\/","title":{"rendered":"Load Cell Universal Hardness Tester"},"content":{"rendered":"<p><strong>Load Cell <\/strong>Universal Hardness Tester<\/p>\n<p><em>Model No. <\/em><em>TIME-Universal<\/em><em>\u00a0 <\/em><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-105\" src=\"http:\/\/titesting.ca\/wp-content\/uploads\/2020\/11\/Load-Cell-Universal-Hardness-Tester-220x300.jpg\" alt=\"TIME-Universal\u00a0\" width=\"220\" height=\"300\" srcset=\"https:\/\/titesting.ca\/wp-content\/uploads\/2020\/11\/Load-Cell-Universal-Hardness-Tester-220x300.jpg 220w, https:\/\/titesting.ca\/wp-content\/uploads\/2020\/11\/Load-Cell-Universal-Hardness-Tester-600x818.jpg 600w, https:\/\/titesting.ca\/wp-content\/uploads\/2020\/11\/Load-Cell-Universal-Hardness-Tester.jpg 699w\" sizes=\"(max-width: 220px) 85vw, 220px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Features:<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Rockwell (Including full regular Rockwell &amp; Superficial Rockwell), Brinell and Vickers<\/strong><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li>The test force is applied via a closed-loop control unit with a load cell, a DC motor and an electronic measurement and control unit that replace traditional dead weights.<\/li>\n<li>The accuracy at all test loads reaches to 0.5%.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Simple plug &#8211; and &#8211; play tech allows for much more quick and easy installation than traditional dead weight type machines.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Higher precision than handle wheel lifting\/dead weight type machines which can be affected by user interaction<strong>.<\/strong><\/li>\n<li>Extended dolphin nose allows vertical test height of 11.8\u201d and throat depth of 8.6\u201d.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Built-in<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Basic functions:<\/strong><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li>Twin tester&#8211;Regular Rockwell &amp; Superficial Rockwell hardness for metal and plastic material.<\/li>\n<li>Light force Brinell and Vickers scales<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Horizontal dolphin nose Indenter is suitable also for internal and external testing.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Testing on Surfaces difficult to reach. Testing internal surface of rings and tubes.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Provided with many features such as high measuring precision, wide measuring range with 30 Rockwell scales.<\/li>\n<li>The tester is suitable for testing of carbon steel, alloy steel, cast iron, non ferrous metal.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li>Automatic testing cycle: Lifting of part, pre-loading, loading, dwell, unloading, results will be finished automatically.<\/li>\n<li>Measuring results digitally displayed and can be printed, or transmitted to external computer automatically via USB port.<\/li>\n<li>Test HR value can be converted to the value of HB, HV, HK and \u03c3b value.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>ROCKWELL Parameters<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Preload<\/strong>\uff1a4N\uff083kgf\uff09, 98.1N (10kgf)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Total test force<\/strong>\uff1a1N(15kgf), 294.3N(30kgf), 441.3N(45kgf),<strong> <em>(superficial)<\/em><\/strong><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li>4N (60kgf), 980.7N (100kgf), 1471N (150kgf) <strong><em>(Regular Rockwell)<\/em><\/strong><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Scales<\/strong><strong>\uff1a<\/strong>HRA\uff0cHRB\uff0cHRC\uff0cHRD\uff0cHRE\uff0cHRF,HRG\uff0cHRH\uff0cHRK\uff0cHRL\uff0cHRM\uff0cHRP, HRR\uff0cHRS\uff0cHRV, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HR15W, HR30W, HR45W, HR15X, HR30X, HR45X, HR15Y, HR30Y, HR45Y ,<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>BRINELL parameters<\/strong>:<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Test force<\/strong>\uff1a 625kgf\uff0c31.25kgf, 62.5kgf\uff0c100kgf, 125kgf, 187.5kgf\uff0c250kgf<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Indenter<\/strong><strong>\uff1a<\/strong> \u03a62.5mm, \u03a65mm, \u03a610mm<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Scales <\/strong>5\/187.5\uff0c 2.5\/62.5\uff0c 2.5\/31.25\uff0c 2.5\/15.625\uff0c<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>\u0095\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 5\/250\uff0c 5\/125\uff0c 5\/62.5\uff0c\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 10\/100\uff0c 10\/250<\/p>\n<p>&nbsp;<\/p>\n<p>\u0095<\/p>\n<p><strong>VICKERS parameters<\/strong>:<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Test force<\/strong>\uff1a 3kgf\uff0c10kgf\uff0c20kgf\uff0c30kgf\uff0c50kgf\uff0c100kgf<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li>Indenter\uff1a 136\u00b0diamond pyramid<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li>Scales: HV3\uff0cHV10\uff0cHV20\uff0cHV30\uff0cHV50\uff0cHV100<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Other Important Parameters:<\/strong><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Load dwell duration<\/strong>\uff1a 2\uff5e50s, can be set and stored<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Resolution <\/strong>\uff1a1HR<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Display<\/strong>\uff1aHigh definition backlight LCD<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Operation<\/strong><strong>\uff1a<\/strong>Menu selectable, Membrane keypad<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Limit setting: <\/strong>Upper\/lower limits setting &amp; alarming<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Data statistics<\/strong><strong>\uff1a<\/strong> , Max., Min., S, R<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li>Curved surface auto correction<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Memory<\/strong>: Max 400 items of test results stored automatically<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Testing Capacity<\/strong>\uff1a300mm (vertical) , 220mm (horizontal)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Dimensions<\/strong><strong>\uff1a<\/strong> 690mm\u00d7280mm\u00d7860mm<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Power supply<\/strong>\uff1aAC, 220V\/110V, 50\uff5e60Hz, 4A (convertible)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Net weight<\/strong>\uff1a86 kg (190lbs)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Gross weight:<\/strong>120kg (265 lbs)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Included Accessories:<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p>&nbsp;<\/p>\n<table width=\"542\">\n<tbody>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\"><\/td>\n<td width=\"114\"><\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">\u00a0 Main TIME-Universal unit<\/td>\n<td width=\"114\">\u00a0\u00a0\u00a0 1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Calibration certificate<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Standard hardness block for Rockwell B scale<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Standard hardness block for Rockwell C scale<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Standard hardness block for Rockwell 30N scale or 30T<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">120\u00b0cone diamond indenter<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">1\/16\u201d carbide ball indenter<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">USB connection cable<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Standard Brinell hardness block for HBW2.5\/187.5\u00a0 or HBW5\/250<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">\u03a62.5mm Ball indenter<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">\u03a65mm Ball indenter<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">40X optical \u00a0Microscope for Brinell measurement<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Mounting screws for indenter<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Standard Flat anvil 150mm dia.<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Standard \u201cV \u201dshape anvil<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Power supply cable<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Screwdriver for indenter mounting<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<tr>\n<td width=\"3\"><\/td>\n<td width=\"422\">Dust cover<\/td>\n<td width=\"114\">1<\/td>\n<td width=\"3\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Load Cell Universal Hardness Tester Model No. TIME-Universal\u00a0 &nbsp; &nbsp; \u00a0 \u00a0 Features: &nbsp; Rockwell (Including full regular Rockwell &amp; Superficial Rockwell), Brinell and Vickers &nbsp; The test force is applied via a closed-loop control unit with a load cell, a DC motor and an electronic measurement and control unit that replace traditional dead weights. The accuracy at all test loads reaches to 0.5%. \u00a0 Simple plug &#8211; and &#8211; play tech allows for much more quick and easy installation &hellip; <a href=\"https:\/\/titesting.ca\/index.php\/product\/load-cell-universal-hardness-tester\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Load Cell Universal Hardness Tester&#8221;<\/span><\/a><\/p>\n","protected":false},"featured_media":105,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/titesting.ca\/index.php\/wp-json\/wp\/v2\/product\/106"}],"collection":[{"href":"https:\/\/titesting.ca\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/titesting.ca\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/titesting.ca\/index.php\/wp-json\/wp\/v2\/comments?post=106"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/titesting.ca\/index.php\/wp-json\/wp\/v2\/media\/105"}],"wp:attachment":[{"href":"https:\/\/titesting.ca\/index.php\/wp-json\/wp\/v2\/media?parent=106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}